Getting started
This guide describes the coming beta of the plug-in. Request beta access now.
What the plug-in does
Prodigy Control for Q-SYS is a plug-in for Q-SYS Designer, one .qplug file. It connects straight to a DirectOut Prodigy.MC, Prodigy.MP or Prodigy.MX over the network and puts the unit into your Q-SYS design:
- Status: the connection, the unit's name, model, firmware, serial and addresses, clock source and sample rate, sync, fitted modules, temperatures, power supplies and warnings, and an overall Q-SYS status for a Status Combiner.
- Channels: for the channels you choose, the unit's channel name, a meter with signal and over LEDs, and a mute button.
- Circle meters and grid meters: many channels at a glance, like Globcon's Meter Eye and the port blocks on its Prodigy.MX home page.
- Mute All: the unit's mute-all for each port, and for the DSP on the MP and MX.
- Input Managers: pick an entry by hand or hand the choice back to the unit, and see which entry is active.
- Snapshots: recall the unit's snapshots by name or by slot.
It talks to the unit directly, on TCP port 5003 for control and 5002 for meters, and needs no Globcon and no OSC server. Every control has a fixed name for control pins and Q-SYS scripts.
It is an operating surface, not a configuration tool. It never writes the unit's system mode (Globcon switches a Prodigy.MP to EASY mode when it connects; this plug-in doesn't) or its network settings, and never sends the reset, reboot or shutdown commands: a check in the plug-in refuses them before anything is sent. It doesn't edit routing, DSP or snapshots; use DirectOut's Globcon for that.
The plug-in is free and never signs in. The pictures in this guide are the plug-in's own pages, drawn from its code with example channel names and levels.
What you need
- Q-SYS Designer, on Windows.
- A DirectOut Prodigy.MC, Prodigy.MP or Prodigy.MX that the Q-SYS Core can reach on TCP ports 5003 and 5002. When you emulate a design, it runs on your PC, so the PC must reach the unit instead.
Installing it
- With beta access on your account, download
ProdigyControl.qplugfrom Account › Beta Releases › Prodigy Control for Q-SYS. - Copy it to Documents\QSC\Q-Sys Designer\Plugins. If the
QSCorPluginsfolder doesn't exist yet, create it. - In Designer's Schematic Library, open Plugins › DirectOut. The plug-in is listed as Prodigy Control. If it isn't there, restart Designer.
- Drag Prodigy Control into the design.
- With the block selected, set Model and IP Address in Properties, then choose the channels to show (Choosing channels).
- Run the design: Emulate (F6) runs it on your PC; Save to Core & Run (F5) runs it on the Core.
The block and its control panel
The block shows DirectOut, the model and the version, for example DirectOut Prodigy.MX over v0.1.0 (DirectOut Prodigy when Model is Auto). Double-click it to open its control panel. Each page of the panel is a tab: Status, a page per channel block, Circle Meters and Grid Meters when they are on, Mute All, Input Managers and Snapshots.
Connecting to a unit
Type the unit's address in the IP Address property. If you leave the property empty, the plug-in uses the IP Address box on its Status page instead. That box keeps its value in the design and can be changed while the design runs, or from a script; changing it connects to the new address.
Leave Control Port (5003) and Meter Port (5002) as they are. They exist for testing against a simulator.
Updating to a new build
Replace the file in the Plugins folder. A plug-in that is already in a design keeps the code it was placed with while the version number is unchanged, as between beta builds. To load the new build into a design, delete the plug-in from the design and drag it in again. Its properties go back to their defaults, and wires to its pins must be made again.
Properties
Every property
Select the plug-in's block to see its properties. Settings that don't apply are hidden: blocks beyond the block count, the port lists of other models, and the meter settings when Channel Meters is off.
| Property | Default | What it does |
|---|---|---|
| Model | Auto | Auto, Prodigy.MC, Prodigy.MP or Prodigy.MX. See Model. |
| IP Address | (empty) | The unit's address. When empty, the IP Address box on the Status page is used. |
| Control Port | 5003 | For testing against a simulator only. |
| Meter Port | 5002 | For testing against a simulator only. |
| Meter Rate | 4 Hz | Off, 1, 2, 4 or 8 Hz. Off opens no meter connection. |
| Channel Mutes | Yes | A mute button for each channel shown. |
| Channel Meters | Yes | A meter, signal LED and over LED for each channel shown. |
| Circle Meters | No | Adds the Circle Meters page. |
| Grid Meters | No | Adds the Grid Meters page. |
| Signal Threshold (dBFS) | −57 | Signal LEDs light at or above this level (−100 to 0). |
| Over Threshold (dBFS) | −2 | Over LEDs light at or above this level or at full scale, and stay lit 1 s (−40 to 0). |
| Input Blocks | 1 | How many input channel blocks to show (0 to 4). |
| Input Block n Port | MADI 1 | The block's port. See Choosing channels. |
| Input Block n First Channel | 1 | The port's channel the block starts at. |
| Input Block n Channels | 8 | How many channels (1 to 128). |
| Output Blocks | 1 | The same for outputs: Output Block n Port, Output Block n First Channel and Output Block n Channels. |
| Input Managers | 4 | How many Input Managers to show (0 to 64). |
| First Input Manager | 1 | The first one shown. |
| Snapshot Buttons | 8 | Recall buttons for slots 1 to n (0 to 32). |
| Debug Output | Off | Basic logs connection events; Verbose also logs every message. See Seeing the plug-in's log. |
Model
With Auto, the plug-in works out the model from the unit's data after it connects, and offers every port of any model. A fixed model gives exactly that model's ports, Input Managers and mute-all buttons. If the unit turns out to be a different model, the plug-in turns channel control off and the Status page says why: channel numbers differ between models.
Choosing channels
A Prodigy.MX has 1,664 inputs and 1,664 outputs, far more than one plug-in should carry, so you pick channels in blocks. A block is a port, a first channel and a channel count: for example MADI 1, from channel 1, 16 channels. Up to 4 input and 4 output blocks of up to 128 channels each can be shown, and each block gets its own page (Channel blocks).
A block names a port, not a raw channel number, so a design made with Auto works on any model. The port list follows Model: with Auto it is Input Block n Port, which lists every port of any model; with a fixed model it is Input Block n Port (MC), (MP) or (MX), which lists only that model's ports. Each model keeps its own choice.
| Port | MC | MP | MX |
|---|---|---|---|
| MADI 1, MADI 2 | 64 each | 64 each | 64 each |
| NET 1 | 128 | 128 | 256 |
| NET 2 | none | 128 | 256 |
| NET 3 to NET 6 | none | none | 256 each |
| Slot 1 to Slot 8 | 8 slots, 8 each | Slots 1–4, 8 each | none |
| Generators (inputs) | 10 | 10 | 8 |
| Input Managers (inputs) | 32 | none | none |
| Summing Buses (inputs) | 32 | none | none |
| Phones (outputs) | 4 | 4 | 4 |
First Channel always allows 1 to 256 and Channels 1 to 128, whatever the port: Designer ignores limits a plug-in changes after its properties are set. A block that runs past the end of its port stops at the port's last channel, and its page title shows the channels it really covers. A channel the unit doesn't have shows - and its controls are disabled.
Meter settings
The unit sends every meter in one frame (16 KB per frame on an MX) at the Meter Rate, so keep the rate modest. Signal and over LEDs use the two thresholds, and so do the circle and grid meters. When Channel Meters is off, the meter properties are hidden and the Circle Meters and Grid Meters pages are not offered.
The plug-in's pages
Status
The first tab shows whether the plug-in is connected, which unit it is talking to, and the unit's clock and health.
The Status page connected to a Prodigy.MP named PA Drive, clocked from NET 1.
Connection
- IP Address: the unit's address. Used when the IP Address property is empty; changing it connects to the new address.
- Reconnect connects again at once. Identify asks the unit to flash its front panel.
- Status: the plug-in's overall status, as a Q-SYS status: OK (green) when connected with nothing to report, Compromised when connected with a warning, Fault when it can't reach the unit or has no IP address, and Initializing while it connects and reads the unit. The messages are listed under Status messages, and it can feed a Status Combiner (Status into a Status Combiner).
- Connected lights once the unit has been read and the link is up. Meters lights while the meter stream is open.
- The text box beside them shows
Connecting...,Reading device...,Connected, or the countdown to the next try, such asRetry in 8 s.
Device
Name, Model, Firmware, Serial, Device IP and MAC, as the unit reports them. Model shows the model the plug-in is using: the Model property's choice, or with Auto the model it detected.
Clock
Clock Source and Sample Rate, then a sync LED for each MADI port, each NET port the model has, and each word clock input: green when the unit reports sync, amber when it reports lock only, off with no lock.
Health
- Temperature 1 and Temperature 2, in °C.
- PSU 1 and PSU 2: the unit's state for each power supply (OK, ERROR, NOT STABLE or OFF). The LED is green for OK and red for ERROR or NOT STABLE.
- Panel Locked lights when the unit's front panel is locked.
- Warning lights, and the box below it shows the text, when the unit reports a warning.
- Modules: one line per fitted module, for example
Slot 1: AES4.IO.
A unit warning, a PSU error or an unstable PSU also set Status to Compromised, with the reason as its text.
Channel blocks
Each input and output block you set up in Properties has its own tab, named after the block and its port, such as In 1 - NET 1 or Out 2 - MADI 1.
Input block 1 on NET 1 of a Prodigy.MX, 16 channels. Channel 3 is clipping; channel 16 is muted.
Channels are laid out 16 to a row. Top to bottom, each one has:
- the unit's name for the channel (its default name when the unit has none);
- a meter in dBFS, from −100 to 0, showing the highest level since the last screen update;
- a signal LED (left), lit at or above the Signal Threshold, and an over LED (right), lit at or above the Over Threshold or at full scale and held for 1 s;
- a mute button.
The box title says which channels the block really covers. A channel the unit doesn't have shows -, and its controls are disabled. Channel Meters and Channel Mutes in Properties turn the meters and the mute buttons off.
Mutes
A pressed mute stays as you set it while the unit is asked. It is kept when the unit confirms it, and goes back to the unit's own state if the unit refuses it, doesn't answer within 5 s, or the link is down. Mutes changed elsewhere (on the unit or in Globcon) show up when the unit reports them.
Generators (sine, white noise and pink noise) have no mute of their own on the unit; their mute buttons switch the generator off and on, as Globcon does. BLDS, the reserved input, the test inputs and the Prodigy.MP's Dirac input have no mute, so their buttons are disabled.
Meters
Meters open after the unit has been read, on TCP port 5002, at the Meter Rate. They read the unit's meter frames for every model, including the older, smaller frames of firmware v0.0 to v0.2 and v1.0 to v1.2. If no meter data arrives for 5 s, the plug-in closes the meter connection and opens it again 2 s later. While the meter link is down, the meters and LEDs go down too.
Circle meters
Turn on Circle Meters in Properties to add a Circle Meters tab. It shows a circle for each channel block: inputs on top, outputs below, four to a row.
Circle meters for two input blocks and one output block on a Prodigy.MX.
- Each channel of the block is a wedge, in channel order, clockwise from 12 o'clock.
- A wedge grows out from the centre with the channel's level: −60 dBFS at the centre, 0 dBFS at the rim.
- It is green, yellow from −18 dBFS, and red from the Over Threshold.
- A red mark on the rim shows while the channel's over LED is lit.
The label under each circle names the block and its channel count, for example In 1 - NET 1 (16 ch). Pressing a circle does nothing.
Each circle is an image the plug-in draws on a button whenever new meter data arrives (about 100 bytes per channel each time), so keep blocks and the Meter Rate modest. With many large blocks, the plug-in spreads the drawing over several screen updates to stay inside Q-SYS's limit on Lua work per call; the circles then update a little less often than the bar meters.
Grid meters
Turn on Grid Meters in Properties to add a Grid Meters tab. It needs no channel blocks: every channel of every port is shown, so one look tells you which feeds are alive.
A Prodigy.MX: NET 1 to NET 4 on the first row; NET 5, NET 6, MADI 1 and MADI 2 on the second.
Each port has a column: its name, the In grid, and the Out grid below. The ports follow the Model property:
| Model | Grids |
|---|---|
| Prodigy.MC | MADI 1, MADI 2, NET 1, Slots |
| Prodigy.MP | MADI 1, MADI 2, NET 1, NET 2, Slots |
| Prodigy.MX | NET 1 to NET 6, MADI 1, MADI 2 |
| Auto | MADI 1, MADI 2, NET 1 to NET 6, Slots |
With Auto, each grid is the size of that port on the model that has the most channels there. Ports and channels the connected unit doesn't have are drawn darker: on a Prodigy.MC, NET 2 to NET 6 and the second half of NET 1.
A Prodigy.MC. NET 1 has 128 channels, two tiles side by side; Slots has a row for each of the 8 slots.
A Prodigy.MP. Its 4 slots make a Slots grid of 4 rows: here an AES card in Slot 1 and an analog card in Slot 2, with an aux pair in and four outputs on NET 1.
- One cell per channel, 8 to a row, in tiles of 8 × 8 = 64 channels. A 256-channel NET port on the MX is 2 × 2 tiles; a 64-channel MADI port is one tile.
- A cell is dark below the Signal Threshold, then green (dimmer below −36 dBFS), yellow from −18 dBFS, and red from the Over Threshold. Red is held for 1 s.
- The frame around a grid shows the port's sync state, as the sync LEDs on the Status page do: green for sync, amber for lock only, grey for no lock. Slots have no sync state and stay grey.
Hovering over a grid in Designer shows its name, such as Grid Meters NET 3 Out. Pressing a grid does nothing.
The grids read the levels straight from the newest meter frame, so they cost no extra network traffic from the unit and need no channel controls. Like the circles, each grid is an image on a button (a 256-channel grid is up to about 6 KB, sent again on every update), and the drawing is spread over screen updates to stay inside Q-SYS's limit on Lua work per call. With all 18 grids of Auto on, each grid may update a little less often than the Meter Rate.
Mute All
The Mute All tab has one toggle per port group of the unit. Pressing one sets that group's mute-all on the unit; the button is red while it is on.
A Prodigy.MX with NET 2 and DSP muted.
| Model | Buttons |
|---|---|
| Prodigy.MC | MADI 1, MADI 2, NET 1, Slots |
| Prodigy.MP | MADI 1, MADI 2, NET 1, NET 2, Slots, DSP |
| Prodigy.MX | MADI 1, MADI 2, NET 1 to NET 6, DSP |
| Auto | All of them; the ones the connected unit lacks are disabled |
Slots is one button for all of the unit's slots. Like the channel mutes, a button stays as you set it while the unit is asked, and goes back to the unit's state if the unit refuses or doesn't answer within 5 s.
Input Managers
An Input Manager (input router) picks one of up to six sources by priority and signal. This tab lets you override that choice and shows what the unit is doing.
A Prodigy.MP driving a PA. Each console channel has a manager with AES as entry 1 and an analog copy as entry 2. Console 2's AES is silent, so the unit has switched its four managers to analog.
- Input Manager: the unit's label for it, or
IM 3when it has none. - Select:
AUTO, or one entry by hand. Each entry that has a source is listed with its number and the source's name, for example2: C1 Left Analog. ChoosingAUTOhands the choice back to the unit. - Active: the entry the unit is using now.
- Per entry, 1 to 6: an active LED, a signal LED (lit when the unit reports the entry is not silent) and the source's name.
A new choice stays as you set it while the unit is asked, and goes back to the unit's choice if the unit refuses or doesn't answer within 5 s. When a manager is stereo-linked, a choice made by hand is also sent to its partner, as Globcon does.
Input Managers and First Input Manager in Properties choose which managers are shown: by default managers 1 to 4. The Prodigy.MC and MP have 32, the MX 64. With a fixed Model, rows stop at that model's last manager; with Auto, rows past the connected unit's last manager show - and are disabled.
Snapshots
The Snapshots tab recalls what is stored on the unit. It doesn't store or change snapshots.
Three stored snapshots, with Snapshot Buttons set to 3; Show was recalled last.
- Snapshot lists the unit's stored snapshots in the unit's own order. A snapshot without a name is listed as
Slot 3and so on. When two have the same name, the slot is added, as inShow (slot 4). - Recall recalls the one selected.
- Last Recalled shows the snapshot the unit says it recalled last.
For slots 1 to n (Snapshot Buttons in Properties, 8 by default, up to 32) there is a recall button named after the snapshot in that slot, its name, and an LED that lights for the last recalled one. The button is disabled when the slot is empty. Slot buttons suit pins and scripts, because a slot number doesn't change when snapshots are renamed.
Controls and pins
Names, numbers and pins
Every control on the plug-in's pages has a fixed name. Wire to it with a control pin, or reach it from a Q-SYS script through the plug-in's component.
- Pins are not on the block until you add them: select the block and tick them under Control Pins in Properties. They are grouped as on the pages, for example Connection › Status.
- A control that repeats is numbered:
InputMute 1,InputMute 2and so on. In Lua it isControls.InputMute[1]. A repeating control with only one copy has no number. - Channel controls (
InputName,InputMute,InputMeter…) count over the channels shown, in block order: input block 1's channels first, then block 2's. - Input Manager entries are numbered
(manager - 1) × 6 + entry:IMEntryName 7is the first entry of the second manager shown. - Pin in the tables below: Output sends the control's value out, Input takes a value in, Both does both.
Status into a Status Combiner
The Status control is the plug-in's overall Q-SYS status, so a Status Combiner can watch the unit with the rest of the system.
- Select the plug-in's block. In Properties, under Control Pins, open Connection and tick Status. An output pin appears on the block.
- Add a Status Combiner (Schematic Library › Control Components) and wire the pin to one of its inputs.
The combiner then shows the plug-in's state and its text, for example Fault - 1: No IP address. OK means connected with nothing to report; Compromised means connected with a unit warning, a PSU problem or a model mismatch. While the unit can't be reached, the status is Fault between tries and Initializing during each try. See Status messages.
Every control
Status page
| Control | Type | Pin | Notes |
|---|---|---|---|
Status | Status | Output | The plug-in's overall Q-SYS status. Wire it to a Status Combiner. |
Connected | LED | Output | Unit read and link up |
ConnectionStatus | Text | Output | Connected, Retry in 8 s… |
IPAddress | Text | Both | Change it to connect to another unit |
Reconnect | Trigger | Input | Connect again now |
Identify | Trigger | Input | Flash the unit's front panel |
MetersConnected | LED | Output | Meter stream open |
DeviceName, DeviceModel, Firmware, Serial, DeviceIP, MAC | Text | Output | From the unit |
ClockSource, SampleRate | Text | Output | For example 48 kHz |
SyncMADI 1–2 | LED | Output | Green sync, amber lock only |
SyncNET 1–n | LED | Output | 1 on the MC, 2 on the MP, 6 on the MX and with Auto |
SyncWCK 1–2 | LED | Output | Word clock |
Temperature 1–2 | Text | Output | °C |
PSU 1–2 | Text | Output | OK, ERROR, NOT STABLE or OFF |
PSUOK 1–2 | LED | Output | Green OK, red error |
Modules | Text | Output | One line per fitted module |
Warning | Text | Output | The unit's warning |
WarningActive | LED | Output | Lit while there is a warning |
FrontPanelLocked | LED | Output | Front panel locked |
Channels
| Control | Type | Pin | Notes |
|---|---|---|---|
InputName, OutputName | Text | Output | The unit's channel name |
InputMute, OutputMute | Toggle | Both | With Channel Mutes on |
InputMeter, OutputMeter | Meter | Output | dBFS, −100 to 0; with Channel Meters on |
InputSignal, OutputSignal | LED | Output | At or above the Signal Threshold |
InputOver, OutputOver | LED | Output | At or above the Over Threshold, held 1 s |
Mute All
| Control | Type | Pin | Notes |
|---|---|---|---|
MuteAllMADI1, MuteAllMADI2 | Toggle | Both | Every model |
MuteAllNET1–MuteAllNET6 | Toggle | Both | The NET ports the model has |
MuteAllSlots | Toggle | Both | MC and MP |
MuteAllDSP | Toggle | Both | MP and MX |
Input Managers
| Control | Type | Pin | Notes |
|---|---|---|---|
IMLabel | Text | Output | The manager's label |
IMSelect | Combo box | Both | AUTO or an entry, such as 2: C1 Left Analog |
IMCurrent | Text | Output | The active entry |
IMEntryName | Text | Output | An entry's source |
IMEntryActive | LED | Output | The entry is the active one |
IMEntrySignal | LED | Output | The unit reports the entry is not silent |
Snapshots
| Control | Type | Pin | Notes |
|---|---|---|---|
SnapshotSelect | Combo box | Both | The stored snapshots |
SnapshotRecall | Trigger | Input | Recall the one selected |
SnapshotLast | Text | Output | Last recalled |
SnapshotButton | Trigger | Input | Recall slot n |
SnapshotName | Text | Output | Slot n's snapshot |
SnapshotActive | LED | Output | Slot n was recalled last |
Circle and grid meters
InputCircle and OutputCircle (one per channel block), and InputGrid and OutputGrid (one per port, in the order of the Grid Meters page), are buttons that carry the meter pictures. They have no pins.
Troubleshooting
Fixing common problems
Start with the Status line on the plug-in's first tab: it says what the plug-in is doing and, when something is wrong, why.
Status messages
| Status | Q-SYS state | Meaning |
|---|---|---|
OK | OK | Connected, nothing to report. |
No IP address | Fault | Neither the IP Address property nor the box on the Status page has an address. |
Connecting to 10.0.0.5 | Initializing | Opening the connection; after the first try it adds the attempt number. |
Reading device | Initializing | Connected and reading the unit's whole state. |
Connect timed out - retry in 8 s | Fault | No connection: the reason, then the countdown to the next try. |
A warning, PSU 1 error, PSU 2 not stable | Compromised | Connected, and the unit reports a problem. |
Unit looks like Prodigy.MP, Model property says Prodigy.MC: channel control is off | Compromised | The Model property doesn't match the unit. Set Model to the unit's model, or to Auto. |
Model not recognised: set the Model property | Compromised | With Auto, the plug-in couldn't tell the model from the unit's data. Set Model by hand. |
The reasons a connection is dropped include Connect timed out (no connection within 10 s), No data for 30 s and No reply to the full read, as well as errors reported by Q-SYS.
The unit doesn't connect
The plug-in connects to the unit on TCP 5003 (control) and TCP 5002 (meters). The Q-SYS Core must reach the unit on both; when you emulate, the PC running Designer must. Leave Control Port and Meter Port at 5003 and 5002 for a real unit.
When the unit goes away
The plug-in pings the unit every 5 s. After a drop it tries again every 10 s for the first minute, every 30 s until 5 minutes, every 60 s until 30 minutes, then every 5 minutes, and the Status page counts down. Reconnect tries at once. When the unit comes back, the plug-in reads it again, even if it is now a different model.
Meters don't move
- Meter Rate is Off, or Channel Meters is off.
- The meter stream opens only after the unit has been read; watch the Meters LED on the Status page.
- If no meter data arrives for 5 s, the plug-in closes the meter connection and tries again 2 s later. If Status is OK but the Meters LED stays off, check that TCP 5002 isn't blocked.
A channel shows "-" and is disabled
The unit doesn't have that channel: the block runs past the end of its port, or with Auto the port doesn't exist on this model (Slot 5 on a Prodigy.MP, for example). See Choosing channels.
"Max execution limits exceeded"
Q-SYS stops any single piece of plug-in Lua (one event or timer tick) after about 200,000 instructions. Reading a whole Prodigy takes far more, so the plug-in reads the unit, updates its controls and draws its meters a slice at a time. If Designer or the Core ever reports this error for the plug-in, please report it with your property settings and the unit's model.
A new build doesn't seem to load
A plug-in already in a design keeps the code it was placed with while the version number is unchanged. Delete it and drag it in again; see Updating to a new build.
Seeing the plug-in's log
- Select the plug-in's block and set Debug Output to Basic (connections, reads, drops and retries) or Verbose (every message sent and received as well, except pings).
- Set Designer's own Show Debug property for the block to Yes.
- Run the design. The Debug Output pane opens under the plug-in's control panel.
Lines start with [Prodigy].
Still stuck
Send feedback with what you did and what you expected. Please include the plug-in's version (on its block, for example v0.1.0), your Q-SYS Designer version, whether the design ran in emulation or on a Core, the unit's model and firmware (both on the Status page), and the lines from the plug-in's log.