Prodigy Control for Q-SYS beta support

Installing the plug-in

Adding the .qplug file to Q-SYS Designer, placing it in a design and connecting it to a Prodigy.

Beta documentation

Prodigy Control for Q-SYS is in beta. These pages describe the current beta builds, which are pre-release software: what they say may change before the first production release, and parts marked Beta are new or still being tested. Downloading the beta needs an account with Prodigy Control for Q-SYS beta access (ask for it here). Tell us if something here is wrong.

The plug-in is a single file. Designer lists it once the file is in your Plugins folder; from there it goes into a design like any other component.

What you need

  • Q-SYS Designer. This beta was tested with Designer 10.5.1 on Windows.
  • A DirectOut Prodigy.MC, Prodigy.MP or Prodigy.MX that the Q-SYS Core can reach on TCP ports 5003 and 5002. In emulation the design runs on your PC, so the PC must reach the unit instead.

Install and place it

  1. Get ProdigyControl.qplug.
  2. Copy it to Documents\QSC\Q-Sys Designer\Plugins. If the QSC or Plugins folders don't exist yet, create them.
  3. In Designer's Schematic Library, open Plugins › DirectOut. The plug-in is listed as Prodigy Control. In testing, Designer listed a new file without a restart; if it doesn't appear, restart Designer.
  4. Drag Prodigy Control into the design.
  5. With the block selected, set Model and IP Address in Properties, then choose the channels to show (Channel blocks).
  6. Run the design: Emulate (F6) runs it on the PC; or save it to the Core and run it there.

The block and its control panel

The block shows DirectOut, the model and the version, for example DirectOut Prodigy.MX over v0.1.0 (DirectOut Prodigy when Model is Auto). Double-click it to open its control panel. Each page of the panel is a tab: Status, a page per channel block, Circle Meters and Grid Meters when they are on, Mute All, Input Managers and Snapshots.

Setting the unit's address

Type the unit's address in the IP Address property. If you leave the property empty, the plug-in uses the IP Address box on its Status page instead; that box keeps its value in the design and can be changed while the design runs, or from a script. Changing it connects to the new address.

Leave Control Port (5003) and Meter Port (5002) as they are; they exist for testing against a simulator.

Updating to a new build

Replace the file in the Plugins folder. In testing with Designer 10.5.1, a plug-in that was already in a design kept the code it was placed with when the version number had not changed, as between beta builds. To load the new build into a design, delete the plug-in from the design and drag it in again. Its properties go back to their defaults, and wires to its pins must be made again.