Prodigy Control for Q-SYS is in beta. These pages describe the current beta builds, which are pre-release software: what they say may change before the first production release, and parts marked Beta are new or still being tested. Downloading the beta needs an account with Prodigy Control for Q-SYS beta access (ask for it here). Tell us if something here is wrong.
Start with the Status line on the plug-in's first tab: it says what the plug-in is doing and, when something is wrong, why.
Status messages
| Status | Q-SYS state | Meaning |
|---|---|---|
OK | OK | Connected, nothing to report. |
No IP address | Fault | Neither the IP Address property nor the box on the Status page has an address. |
Connecting to 10.0.0.5 | Initializing | Opening the connection; after the first try it adds the attempt number. |
Reading device | Initializing | Connected and reading the unit's whole state. |
Connect timed out - retry in 8 s | Fault | No connection; the reason, then the countdown to the next try. |
A warning, PSU 1 error, PSU 2 not stable | Compromised | Connected, and the unit reports a problem. |
Unit looks like Prodigy.MP, Model property says Prodigy.MC: channel control is off | Compromised | The Model property doesn't match the unit. Set Model to the unit's model, or to Auto. |
Model not recognised: set the Model property | Compromised | With Auto, the plug-in couldn't tell the model from the unit's data. Set Model by hand. |
The reasons a connection is dropped include Connect timed out (no connection within 10 s), No data for 30 s, and No reply to the full read, as well as errors reported by Q-SYS.
Network ports
The plug-in connects to the unit on TCP 5003 (control) and TCP 5002 (meters). The Q-SYS Core must reach the unit on both; in emulation, the PC running Designer must. If Status goes OK but the Meters LED stays off, port 5002 is the first thing to check. Leave Control Port and Meter Port at 5003 and 5002 for a real unit.
When the unit goes away
The plug-in pings the unit every 5 s. After a drop it tries again every 10 s for the first minute, every 30 s until 5 minutes, every 60 s until 30 minutes, then every 5 minutes, and the Status page counts down. Reconnect tries at once. When the unit comes back the plug-in reads it again, even if it is now a different model.
Meters don't move
- Meter Rate is Off, or Channel Meters is off.
- The meter stream opens only after the unit has been read; watch the Meters LED on the Status page.
- If no meter data arrives for 5 s, the plug-in closes the meter connection and tries again 2 s later. A firewall that blocks TCP 5002 shows as the Meters LED staying off.
A channel shows "-" and is disabled
The unit doesn't have that channel: the block runs past the end of its port, or with Auto the port doesn't exist on this model (Slot 5 on a Prodigy.MP, for example). See Channel blocks.
"Max execution limits exceeded"
Q-SYS stops any single piece of plug-in Lua (one event or timer tick) after about 200,000 instructions, measured in Designer 10.5.1. Reading a whole Prodigy takes far more, so the plug-in reads the unit, updates its controls and draws its meters a slice at a time. Its tests check that no single call goes over 150,000 instructions with the largest settings. If Designer or the Core ever reports this error for the plug-in, please report it with your property settings and the unit's model.
A new build doesn't seem to load
A plug-in already in a design keeps the code it was placed with while the version number is unchanged. Delete it and drag it in again; see Updating to a new build.
Seeing the plug-in's log
- Select the plug-in's block and set Debug Output to Basic (connections, reads, drops and retries) or Verbose (every message as well).
- Set Designer's Show Debug property for the block to Yes.
- Run the design. The Debug Output pane opens under the plug-in's control panel.
Lines start with [Prodigy]. Include them when you report a problem (Reporting a problem).