Beta documentationProdigy Control for Q-SYS is in beta. These pages describe the current beta builds, which are pre-release software: what they say may change before the first production release, and parts marked Beta are new or still being tested. Downloading the beta needs an account with Prodigy Control for Q-SYS beta access (ask for it here). Tell us if something here is wrong.
Every control on the plug-in's pages has a fixed name. Wire to it with a control pin, or reach it from a Q-SYS script through the plug-in's component.
Names and numbers
- A control that repeats is numbered:
InputMute 1, InputMute 2 and so on. In Lua it is Controls.InputMute[1]. A repeating control with only one copy has no number.
- Channel controls (
InputName, InputMute, InputMeter…) count over the channels shown, in block order: input block 1's channels first, then block 2's.
- Input Manager entries are numbered
(manager - 1) × 6 + entry: IMEntryName 7 is the first entry of the second manager shown.
- Pin below: Output sends the control's value out, Input takes a value in, Both does both. Pins are not shown on the block until you add them in Designer.
Status page
| Control | Type | Pin | Notes |
Status | Status | Output | The plug-in's overall Q-SYS status: OK, compromised, fault, not present or initializing. Wire it to a Status Combiner. |
Connected | LED | Output | Unit read and link up |
ConnectionStatus | Text | Output | Connected, Retry in 8 s… |
IPAddress | Text | Both | Change it to connect to another unit |
Reconnect | Trigger | Input | Connect again now |
Identify | Trigger | Input | Flash the unit's front panel |
MetersConnected | LED | Output | Meter stream open |
DeviceName, DeviceModel, Firmware, Serial, DeviceIP, MAC | Text | Output | From the unit |
ClockSource, SampleRate | Text | Output | For example 48 kHz |
SyncMADI 1–2 | LED | Output | Green sync, amber lock only |
SyncNET 1–n | LED | Output | 1 on the MC, 2 on the MP, 6 on the MX and with Auto |
SyncWCK 1–2 | LED | Output | Word clock |
Temperature 1–2 | Text | Output | °C |
PSU 1–2 | Text | Output | OK, ERROR, NOT STABLE or OFF |
PSUOK 1–2 | LED | Output | Green OK, red error |
Modules | Text | Output | One line per fitted module |
Warning | Text | Output | The unit's warning |
WarningActive | LED | Output | Lit while there is a warning |
FrontPanelLocked | LED | Output | Front panel locked |
Channels
| Control | Type | Pin | Notes |
InputName, OutputName | Text | Output | The unit's channel name |
InputMute, OutputMute | Toggle | Both | With Channel Mutes on |
InputMeter, OutputMeter | Meter | Output | dBFS, −100 to 0; with Channel Meters on |
InputSignal, OutputSignal | LED | Output | At or above the Signal Threshold |
InputOver, OutputOver | LED | Output | At or above the Over Threshold, held 1 s |
Mute All
| Control | Type | Pin | Notes |
MuteAllMADI1, MuteAllMADI2 | Toggle | Both | Every model |
MuteAllNET1–MuteAllNET6 | Toggle | Both | The NET ports the model has |
MuteAllSlots | Toggle | Both | MC and MP |
MuteAllDSP | Toggle | Both | MP and MX |
| Control | Type | Pin | Notes |
IMLabel | Text | Output | The manager's label |
IMSelect | Combo box | Both | AUTO or an entry, such as 2: Kick |
IMCurrent | Text | Output | The active entry |
IMEntryName | Text | Output | An entry's source |
IMEntryActive | LED | Output | The entry is the active one |
IMEntrySignal | LED | Output | The unit reports the entry is not silent |
Snapshots
| Control | Type | Pin | Notes |
SnapshotSelect | Combo box | Both | The stored snapshots |
SnapshotRecall | Trigger | Input | Recall the one selected |
SnapshotLast | Text | Output | Last recalled |
SnapshotButton | Trigger | Input | Recall slot n |
SnapshotName | Text | Output | Slot n's snapshot |
SnapshotActive | LED | Output | Slot n was recalled last |
Circle and grid meters
InputCircle and OutputCircle (one per channel block), and InputGrid and OutputGrid (one per port, in the order of the Grid Meters page), are buttons that carry the meter pictures. They have no pins.