Prodigy Control for Q-SYS beta support

Properties

Every setting the plug-in has in Designer's Properties panel, with its default and what it changes.

Beta documentation

Prodigy Control for Q-SYS is in beta. These pages describe the current beta builds, which are pre-release software: what they say may change before the first production release, and parts marked Beta are new or still being tested. Downloading the beta needs an account with Prodigy Control for Q-SYS beta access (ask for it here). Tell us if something here is wrong.

Select the plug-in's block in the design to see its properties. Settings that don't apply are hidden: blocks beyond the block count, the port lists of other models, and the meter settings when Channel Meters is off.

All properties

PropertyDefaultWhat it does
ModelAutoAuto, Prodigy.MC, Prodigy.MP or Prodigy.MX. See Model.
IP Address(empty)The unit's address. When empty, the IP Address box on the Status page is used.
Control Port5003For testing against a simulator only.
Meter Port5002For testing against a simulator only.
Meter Rate4 HzOff, 1, 2, 4 or 8 Hz. Off opens no meter connection.
Channel MutesYesA mute button for each channel shown.
Channel MetersYesA meter, signal LED and over LED for each channel shown.
Circle MetersNoAdds the Circle Meters page.
Grid MetersNoAdds the Grid Meters page.
Signal Threshold (dBFS)−57Signal LEDs light at or above this level (−100 to 0).
Over Threshold (dBFS)−2Over LEDs light at or above this level or at full scale, and stay lit 1 s (−40 to 0).
Input Blocks1How many input channel blocks to show (0 to 4).
Input Block n PortMADI 1The block's port. See Channel blocks.
Input Block n First Channel1The port's channel the block starts at.
Input Block n Channels8How many channels (1 to 128).
Output Blocks1The same for outputs: Output Block n Port, Output Block n First Channel and Output Block n Channels.
Input Managers4How many Input Managers to show (0 to 64).
First Input Manager1The first one shown.
Snapshot Buttons8Recall buttons for slots 1 to n (0 to 32).
Debug OutputOffBasic logs connection events; Verbose also logs every message.

Model

With Auto, the plug-in works out the model from the unit's data after it connects, and offers every port of any model. A fixed model gives exactly that model's ports, Input Managers and mute-all buttons. If the unit turns out to be a different model, the plug-in turns channel control off and the Status page says why (channel numbers differ between models).

Channel blocks

A Prodigy.MX has 1,664 inputs and 1,664 outputs, far more than one plug-in should carry, so you pick the channels in blocks. A block is a port, a first channel and a channel count: for example MADI 1, from channel 1, 16 channels. Up to 4 input and 4 output blocks of up to 128 channels each can be shown. Each block gets its own page (Channel blocks).

A block names a port, not a raw channel number, so a design made with Auto works on any model. The port list follows Model: with Auto it is Input Block n Port, which lists every port of any model; with a fixed model it is Input Block n Port (MC), (MP) or (MX), which lists only that model's ports. Each model keeps its own choice.

PortMCMPMX
MADI 1, MADI 264 each64 each64 each
NET 1128128256
NET 2none128256
NET 3 to NET 6nonenone256 each
Slot 1 to Slot 88 slots, 8 eachSlots 1–4, 8 eachnone
Generators (inputs)10108
Input Managers (inputs)32nonenone
Summing Buses (inputs)32nonenone
Phones (outputs)444
Designer doesn't narrow the limits

First Channel always allows 1 to 256 and Channels 1 to 128, whatever the port: Designer ignores limits a plug-in changes after its properties are set. A block that runs past the end of its port stops at the port's last channel, and its page title shows the channels it really covers. A channel the unit doesn't have shows - and its controls are disabled.

Meters

The unit sends every meter in one frame (16 KB per frame on an MX) at the Meter Rate, so keep the rate modest. Signal and over LEDs use the two thresholds; the circle and grid meters use them too. When Channel Meters is off, the meter properties are hidden and the Circle Meters and Grid Meters pages are not offered.

Debug Output

Basic logs connection events: connecting, the full read, meters opening, drops and retries. Verbose also logs every message sent and received, except pings. The log shows in Designer's Debug Output pane when the block's Show Debug property (Designer's own) is Yes; see Seeing the plug-in's log.