RyCAD.AV is in beta. These pages describe the current beta builds, which are pre-release software: what they say may change before the first production release, and parts marked Beta are new or still being tested. Downloading the beta needs an account with RyCAD.AV beta access (ask for it here). Tell us if something here is wrong.
The schematic says what connects to what. The cabling tools measure the real run: you draw the rooms and the containment in the 3D Workspace, and RyCAD.AV finds each cable's route over it and adds up its length.

The cabling tools are the newest part of RyCAD.AV and the least used so far. Treat the lengths as a first estimate and check them against your plans. The heights, allowances, slack and fill limits they use are the plug-in's own proposals until you confirm them, and there is no settings page for them yet. A path, a drop point or a room outline that you move or erase without RyCAD.AV is drawn back as it was the next time the plan is redrawn; reading such edits back is not written yet.
How it works
- Rooms. Draw each room's outline. Racks, drop points and loudspeakers inside it take the room.
- Drop points. Place the floor boxes, wall boxes, stage boxes and pull boxes where cables start or end.
- Cable paths. Draw the tray, ladder, conduit and other containment, joined to the drop points and to the racks.
- Route cables. RyCAD.AV finds every circuit at its two ends, routes it over the network of paths and calculates its length.
- Use the result. Lengths show in the Inspector, the Circuit Schedule and the VectorLabel export; the Cable Pull lists what to pull; the cabling sheets and the riser put it on paper.
Everything is drawn at world size in the 3D Workspace, where your racks and equipment already are, so the lengths are measured where the equipment is. Paths, drop points and cables are linked by id, never by name. Click Work Area › 3D Workspace (or type AV3D) before you start. Put the building's drawings in as xrefs at 0,0 to draw over; see the 3D Workspace.
Rooms
- Click Cabling › Room (or type
AVROOM). The Draw Room tab appears. - Set Draw Room › Shape: Rectangle takes two opposite corners; Free corners takes each corner in turn, and Enter or Close finishes (Undo drops the last corner).
- If you like, set Draw Room › Name (empty gives the next free name, ROOM 1, ROOM 2 and so on) and Draw Room › Height (the house room height is 10 ft; you can type any unit, such as
9'6"or3000mm). - Click the corners. The outline follows the cursor with the room's name where its label will go.
A room is a single object holding its outline, name and number. Select it and edit its Name, Number, Description and Height in the Inspector; Go to room there takes you to it from above.
- Racks, drop points and loudspeakers inside the outline take the room. That fills the room in device headers, the Device Listing and the VectorLabel Room columns. If one already had a different room typed, RyCAD.AV reports it and leaves it.
- A room drawn inside another becomes part of it.
- Move a room with
MOVE, a grip orROTATEand RyCAD.AV works out again what it holds: what lies in it now takes it, and what it left takes the room that holds it, or none. The contents stay where they are. - Draw Room › Select takes a closed polyline you already drew as the outline of the next room (you can erase it; the room draws its own). Draw Room › Refresh adopts rooms that were moved or retyped without RyCAD.AV.
Drop points
- Click Cabling › Drop Point (or type
AVDROP). The Place Drop Point tab appears. - Set Place Drop Point › Kind: floor box, wall box, ceiling, stage box, pull box or other.
- Leave Place Drop Point › Code empty for the next free letter (I and O are skipped), or type one. Set Place Drop Point › Height above the floor in the drawing's units, or with a unit such as
450mmor18in. Empty uses the kind's own: a ceiling box at the room height, any other on the floor. - Click each place. Each click is one drop point. Press Enter to finish.
A drop point picked on a cable path is inserted in it, and the path splits there. A drop point picked at the end of a path that is a rack's entry, or another drop point, is refused: draw a path to it instead. Its room is the one whose outline holds it.
Place Drop Point › Leader moves a drop point's code away from its symbol on a leader line, so it does not crowd a busy plan. Pick the drop point, then a point for the code; press Enter instead of a point to put the code back.
Cable paths
- Click Cabling › Cable Path (or type
AVCABLEPATH). The Draw Cable Path tab appears. - Choose Draw Cable Path › Containment: tray, ladder, basket, conduit, trunking, J-hooks, trench, underfloor or free air.
- Set Draw Cable Path › Height in the drawing's units, or with a unit such as
2700mmor9ft. Empty uses the containment's own: 9 ft for overhead kinds, floor level for conduit, trench and underfloor. - Leave Draw Cable Path › Path ID empty for the next free ID (CP-01, CP-02 and so on), or type one. Tick Draw Cable Path › Repeat to be asked for another path straight away.
- Click the path's points. Press Enter at the last one.
A path whose end you pick on a drop point, or inside a rack's footprint, ends there, with a vertical run down or up to it. An end you pick on another path splits that path and joins it there. Each path's tag reads its ID.
To change paths you have already drawn, select them and use the buttons on the tab. Draw Cable Path › Properties sets the containment, the size (a type such as 1" EMT or 12x4 TRAY, which gives the fill limit; None removes it) and the location text. Draw Cable Path › Delete removes paths; nodes left with two paths heal. Draw Cable Path › Regen redraws every room outline, path and drop point from the data.
Route cables and calculate lengths
Click Cabling › Route Cables (or type AVROUTECABLES). RyCAD.AV finds every circuit, multicore and spare at its two ends (its rack's entry, its drop point or its loudspeaker) and routes it over the paths, taking the shortest of its alternatives. Where no route exists it estimates from the positions instead.
A cable's length is the route plus the extras: the legs inside racks, equipment tails, jackfield swan-necks, false-floor depth, slack at drop points and rack entries, and service loops. It is then rounded up to a stock length of the cable type. A length you typed yourself, or a standard or physical length, is never overwritten.
The command prints one line for each route (letter, how the length was worked out, the length and the paths) and a summary of what could not be routed and why. The calculated lengths appear in the circuit's cable length in the Inspector, in the Circuit Schedule, and in the VectorLabel export. A typed length, or a physical cable's measured length, wins over the calculated one on the labels. To store the routes without changing any length, choose Analyze at the command line when it asks.
See and change a route
- Cabling › Show Route (or
AVSHOWROUTE): pick a circuit's route in the plan. Its paths are selected, and its route and the alternatives are listed shortest first, the current one starred. Choose Alternative and a letter to keep another one, Release to let the next run take the shortest again, or Edit to open Edit Cabling. To find a circuit by its number, cable name or Run ID instead of picking it, choose Name. - Cabling › Edit Cabling (or
AVEDITCABLING): pick a cable path to see its containment, length, location and fill, and every circuit and cable routed through it, or pick a circuit to see its alternatives. Choose another route for a circuit, or release a chosen one. The change is one undo step.
Edit Cabling also does two things from its command-line choices. Spares adds spare cables (pre-cabling) between two drop points or racks that you name, of a cable type and a quantity, numbered by their ends (A-B.1, A-B.2) and routed and measured at once. RunId puts the selected circuits in the physical cable with that Run ID, which is created if it does not exist; their length then becomes the cable's.
The cable pull
Click Cabling › Cable Pull (or type AVCABLEPULL) to save the Cable Pull report as CSV, Excel CSV (semicolons, for European Excel) or XLSX, beside the drawing by default. Choose how it is grouped:
- Cables: a row for each circuit and cable, with its ends, route, alternative letter, length and how the length was found. Spares are included.
- Paths: a row for each cable path, with its fill.
- Pairs: a row for each pair of ends and cable type.
You can also preview the Cable Pull in the Reports palette and put it on a sheet; Sheets › Reports lists it with the Drop Point Schedule and the Containment Fill. See Reports and the Device Listing.
Cabling sheets and the riser
These make sheets in the usual way (see Sheets, title blocks and revisions) and update in place when you run them again.
- Cabling › Cabling Sheet (or
AVCABLINGSHEET) makes a sheet of the whole project or one room. Choose Location (AV-1xx: rooms, racks, drop points and paths with their IDs), Conduit (AV-5xx: paths tagged with size, cable count and fill) or Cabling (AV-5xx: the paths frozen and each run between two ends drawn as arcs or home runs, with its quantity and cable type). It has the title block and a locked viewport onto the plan at 1/4 in = 1 ft (smaller if it does not fit), with the tags in paper space. - Cabling › Riser (or
AVRISER) draws the riser diagram on an AV-5xx sheet from the network: rooms as boxes on their levels, the vertical paths between them with their IDs and sizes, and the drop points and racks they serve.
Good to know
- The records are the truth. Paths, drop points and room outlines are drawn from them as ordinary lines, blocks and text, and their heights are kept in the data, not in the lines. If the plan looks wrong, Draw Cable Path › Regen redraws it from the records.
- Everything is by id. Renaming a room or a drop point does not break a route.
- The fill limits for tray, basket and conduit sizes are general working values rather than figures from a particular code. Check them against the code you work to.