RyCAD.AV is in beta. These pages describe the current beta builds, which are pre-release software: what they say may change before the first production release, and parts marked Beta are new or still being tested. Downloading the beta needs an account with RyCAD.AV beta access (ask for it here). Tell us if something here is wrong.
A panel view is the physical face of a connector panel: where each connector goes, what it is called and how the plate is cut. It is drawn at 1:1, and each hole belongs to one socket of the panel's device, so a rename in the schematic reaches the panel at once.

Panels are a preview. They are newer and less tested than the schematic and the sheets, and the connector drawings need a check before you cut metal; see Good to know.
What a panel view is
A panel is one device in the schematic, with a socket for each connector, and one drawing of its face. The two are joined by ids, never by matching names:
- Rename the panel, a connector or a far-end device, change a circuit number, and the panel's labels redraw in the same undo step.
- Labels, pair captions, group brackets and colour tabs are worked out for you. Anything you type into a hole, a label, a caption or a colour, is kept as your own.
- Each panel view is a single drawing object, and the drawing shows and plots without the plug-in, like everything RyCAD.AV draws.
Panel views live in the Panels work area, between the Schematic and the 3D Workspace. Click Work Area › Panels (or type AVPANELS) to go there. The drop-down under that button lists the panel pages by name. Panels print on panel pages, one page for each panel sheet.
The kinds of panel you can draw are rack panels (1 U to 3 U, with D-series or speakON holes, and a 2 U modular plate with UNIV sub-plates), 1- to 4-gang wall plates, floor boxes and stage boxes, plus a custom panel of any width and height and a custom rack panel of 1 to 20 U.
To design a panel first
The Panel Builder lets you lay out a panel before it exists. It makes the schematic device and its panel view together.
- Click Panels › Panel Builder (or type
AVPANELBUILDER). The RyCAD.AV: Panel Builder window opens with the heading Design a panel, then create its schematic device. - Type a Name for the panel and choose a Template, such as 1 U rack panel, 12 D-series holes. With Custom panel, a Size appears for the width and height in the drawing's units (blank is 200 × 100 mm). With Custom rack panel, Rack units (U) appears, a whole number from 1 to 20 (blank takes the fewest that hold the rows).
- Leave Label distance empty for the house distance, or type how far each label sits from its connector; the box shows the drawing's unit, such as Label distance (in).
- Describe the connectors in the grid, one row for each kind. A row has a Quantity, a Connector, a Model (the drawing of the part), a View (another drawing of the same part, when the model has one; see below), an Accessory and whether its Cover is drawn closed or open, a Direction, a Name prefix, a Group and an Arrangement (Horizontal, Vertical or Square). The Quantity and Name prefix headings are cut short when the window is narrow; widen it to read them. For example, 4 of NC3FD-L-1 with the prefix MIC gives MIC 1 to MIC 4. A row with a Group name (see Connector groups) is named after the group instead. Click Add row for another kind of connector, and Remove row to drop one.
- Watch the live preview: it is the panel as it will be drawn, with each connector numbered. Under it, a count such as 8 of 12 holes. says how many holes the template has used. Use the wheel or pinch to zoom, drag to pan, and double-click to fit.
- Leave Both sides ticked unless you want a socket on one side of the device for each connector. Ticked, each connector has one socket in the middle of the device, and circuits connect to it from either side.
- Click Create, then click where the panel view should go. The device and its layout are made in one undo step. Cancel closes the window and makes nothing.

A row's Direction follows its connector until you choose one: a female XLR (the XLR3F in the picture) is In, a male XLR and a speakON are Out, and etherCON, RJ45, fibre and most others are In/Out. You can change it later in the panel's Inspector. A connector from the library (marked (library)) comes into the drawing with the panel. Edit connectors… closes the builder and opens the connector types (see Connecting devices).
Clicking a row's Connector or Model opens a search over connector types and models together, with a preview. The model starts at Default, the connector type's own model; for XLR3F that is Neutrik NC3FD-L-1, as the picture shows. A part number typed in full is selected, and Enter sets the model and the type it fits. A details pane beside the list shows the model's drawing, make, model, type, mounting, gender and notes.
To draw the view of a panel you already have
If the panel is already in the schematic (see Panels, jackfields and other special devices), make its view from there.
- Click Panels › Panel View (or type
AVPANEL). The Panel View tab appears. - In Panel View › Panel, search for the panel. Panels without a layout come first. Automatic takes the panel of the view you selected, or the first panel without a layout.
- Choose a Panel View › Template. Auto lets RyCAD.AV choose the smallest template that holds every port. For a custom panel also set Panel View › Width and Panel View › Height; for a custom rack panel set Panel View › Rack U. RyCAD.AV refuses a size too small for the panel's connectors and tells you the size it needs.
- Set Panel View › Label Distance (how far each label sits from its connector) and Panel View › Placement: the next free place in the Panels area, or a corner you pick.
- Click Panel View › Create. The layout is built from the device and the view is drawn at 1:1.
Two more buttons on the tab: Panel View › Draw draws the view of a panel that already has a layout but no view, and Panel View › Rebuild arranges a panel again on another template (pick the view). Holes you placed by hand stay where they are. An empty setting keeps the panel's own.
A view placed where no panel page holds it gets a page, so each panel page prints as a panel sheet. When the last row of panel pages is used, a new row of ten is added.
To delete a panel's layout and view but keep its device, click Panels › Panel View and choose Delete at the command line. To make a view for a panel device that has none, you can also select the device in the schematic and click Create panel view in its Inspector section.
Placing, moving and editing connectors
To place connectors by hand
- Click Panels › Panel Connector (or type
AVPANELCONNECTOR) and pick the panel view. The Panel Connector tab appears. - On the tab set Panel Connector › Connector (the type each pick fits, or Each socket's to use every port's own part), Panel Connector › Model (the drawing) and Panel Connector › Cut-out code.
- Click on the plate. Each click places one connector, snapped to the template's grid, for the panel's next port without a hole.
- For several at once use Panel Connector › Array (a row) or Panel Connector › Grid (rows and columns). Then use Panel Connector › Move, Panel Connector › Bind (tie a hole to a port by name, or make it a spare) and Panel Connector › Remove to adjust holes.
A selected panel view has grips: one for each connector, and one on each corner. Drag a connector anywhere on the panel: it snaps to a free slot of the grid within 12 mm, and otherwise stays where you drop it, on the plate or off it. Its socket, caption and label go with it. Drag a corner to resize a custom, floor-box or stage-box panel; a rack panel takes the whole rack units its new height rounds to. Every drop is one undo step.
In the Inspector
Select a panel view to see its Panel section in the Inspector (Devices › Inspector). It holds the panel's Name, Display tag, Template (with Re-arrange), Finish, Label side and Label distance, and the list of connectors. For the selected connector you can set its Name, Display tag, Caption, Label, Tab, Label colour, Connector, Model, View (when the model has more than one drawing), Angle (turn it 90 degrees either way), Accessory or cover, and its own Label side and distance. Each Apply is one undo step. A name typed for a connector bound to a socket renames that socket in the schematic too.
The Socket column says which socket of the panel's device each connector is bound to. Double-click it to choose another socket, or Unbound (spare). Choosing a socket that another connector uses takes it from that connector, which becomes a spare, and says so.
The Edit Connectors grid
For a whole panel at once, use the spreadsheet: select a panel view and click Panels › Edit Connectors (or type AVPANELCONNECTORS). It stays open beside the drawing, with a row for each connector and columns for the name, display tag, group and group style, caption, label, connector, model, view, accessory (with closed or open, and flip), angle, label side and distance, and tab and label colours.
- Click, Shift-click and Ctrl-click select cells. Type to replace a value, press F2 to edit, and Delete to clear.
- Ctrl+C and Ctrl+V copy and paste to and from Excel. One value pasted over several cells fills them all.
- Fill down (Ctrl+D), Fill series (Ctrl+Shift+D, which counts OUT-08, OUT-09 and so on) and Fill right (Ctrl+R) fill from the first cell. Undo and Redo work inside the window.
- Auto-number… numbers the selected cells with a prefix, a start, a step, padding and a suffix, in the list's order or across or down the panel. To the last connector carries on to the end.
Nothing reaches the drawing until you click Apply, which writes every change as one undo step; OK applies and closes. A cell that cannot take its value is marked and stops Apply.
Keeping the panel and the device in step
If connectors and sockets get out of step, select the panel view and click Panels › Sync Connectors (or type AVPANELSYNC). The window lists the differences: connectors with no socket, sockets with no connector, and names, connectors and directions that differ. For each row choose what to do: add a socket for a connector, add a connector for a socket, bind them, copy a name or a connector either way, or leave it. What is missing is ticked and added by default. A bind by matching name is only suggested and starts unticked, so nothing is ever bound by name without your say. Apply does everything ticked in one undo step. The same window opens from the panel's Inspector and from a connector's right-click menu.
Connector groups
A connector group frames a few connectors together under one name, such as the Tie Line connectors of a mix position or the outputs of one amplifier. The panel draws a border or a bracket round them with the group's name in its top edge. Each connector in the group is named after it, Tie Line 1, Tie Line 2 and so on, with the display tag just 1, 2, so the number is what shows above the connector.
- In the Panel Builder type a name in a row's Group cell. The row's connectors are named and tagged that way, and rows with the same group name make one group. Or, on a panel you have, tick connectors in the Inspector's Connectors list, open Connector groups, type a name under New group and click Group ticked.
- Choose the style. Settings › Panels sets the default for the drawing, Connector group style: Square Border, Rounded Border, Bracket or Rounded Bracket (a rounded border unless you choose another). A group can use its own: pick it in the Inspector's Connector groups section (Group style) or in the Group style column of the Edit Connectors grid. Rounded corners are a quarter of an inch.
- Select the panel view to see each group's outline as a faint frame, even for a bracket, with grips on its corners and on the middle of its top edge. Drag a corner to size the group; drag the top grip to move the group with its connectors. A connector in a group can only be moved inside its outline.
- Drag a connector far outside its group and a question asks whether to remove it from the group. Yes takes it out and leaves it where you dropped it, with the name and tag it had. No puts it back inside.
Renaming a group in the Inspector renames its connectors and keeps their numbers. Add ticked adds connectors to the selected group and numbers them on; Take out ticked removes them, and they keep their names, so the numbers left in the group may have a gap until you click Renumber. Fit outline fits the outline round the connectors again. In the Edit Connectors grid, type a group name in a connector's Group cell to put it in that group (a new group is made if there is none), or clear the cell to take it out.
Groups that RyCAD.AV makes itself when it names runs of connectors (HL MAIN 1-2 and so on) use the same default style, and can be given their own in the same place; a group you restyle or rename is kept when you re-arrange the panel.
The panel's device in the schematic draws an outline round each group's connectors with the group's name as a header, so the same grouping shows on the schematic.
Connector models and their drawings
Each connector is drawn as a manufacturer's front view (Neutrik, Link and others) when the local connector-model store has one, and as a generic symbol when it does not. A panel shows only what you see from the front of the plate: the maker's lettering, logos and pin numbers are left out. The model a connector draws is its own, else its part's, else the default of its connector type.
A model can have more than one drawing, called views. Its usual drawing is the Standard view. A Neutrik TOP connector may also have Without covers, which leaves out the flap that covers the connector. Choose the View for a connector in the Panel Builder row, in the connector fields of the Inspector or in the Edit Connectors grid; only the views the connector's model has are offered, and changing to a model without that view puts the connector back to Standard. Wherever the drawing set uses a view other than Standard, the Panel Connectors schedule on the cover sheet gets one more picture column for it, after the Standard picture.
- Click the arrow under Panels › Connector Models to choose List Models (how many models the store holds by family, and the models of a family you type), Default Models (each connector type's default), Import Models (build your own store from the local manufacturer sources) or Reload Models (read the stores again and redraw the panels). The main button is
AVCONNECTORMODELS. - In a connector search, right-click a model for Open product page or Set as default for its connector type. Models marked check drawing need a look; models marked no drawing have none in the store.
- RJ45 jacks can be searched by their traits:
cat6a shielded keystoneorcat6 UTP punch-down. STP means shielded and UTP unshielded. - To change a part's drawing, click Panels › Connector Models › Edit Connector Part (2D) (or type
AVCONNECTOREDIT2D), pick a connector on a panel view, or choose to name a part or make a new one. The Block Editor opens on the part's own front view, flat and in millimetres, with the part's flange, screw holes, cut-out and contact area as guides. It shows the part's lettering, which panels leave out. Draw, paste or import, then use Save, Save As… or Discard on the RyCAD.AV Edit tab. Panels › Connector Models › Edit Accessory (2D) (AVACCESSORYEDIT2D) does the same for an accessory's closed and open views side by side. These two editors are new, and not every AutoCAD step of them has been checked yet.
The cut-out codes a model carries (D, AB, G, KEYSTONE, OTHER and your own) are listed in Settings › Cut-out Codes. Accessories fit a connector by its cut-out code.
Back boxes and wall plates
A wall plate or floor plate can sit in a back box, and the box decides how big the plate is.
- Select the panel view and look at the Panel section of the Inspector.
- Choose a Box type. The list is the boxes in Settings › Panel Boxes, each with its size in the drawing's units. A rack panel has no box.
- Choose a Mounting: Not set, Surface or Flush. A surface plate is the box's front. A flush plate is the box plus an overhang on every side, which you set in Overhang per side (1 in to begin with).
The plate's width and height change at once, in one undo step. A size you type afterwards stays, and reads as a custom size.
A box that holds gang plates, such as an in-wall display box, works as a host. Choose it for a plate and RyCAD.AV makes a box assembly, a panel of its own named after the plate and BOX, that draws the box's front with the plate in its opening. Run Panels › Panel View to place it. Select the assembly and its Inspector lists the box's Openings, each with a list (Empty, Blank plate, New 1-gang plate, or a 1-gang plate that is in no other box) and Up and Down buttons. Each plate stays a panel of its own, with its own connectors.
Your own boxes
Settings › Panel Boxes lists the stock boxes first, read-only (1- to 6-gang US 2 × 4 wall boxes, 4 in and 4-11/16 in square boxes, NEMA 1 enclosures, and some FSR, Wiremold/Legrand and Extron boxes), then your workgroup's, then your own. Click New box to add one: an id, a name, the width and height in millimetres, and optionally depth and gangs, and which mountings it supports. Tick Sizes checked against the maker's drawing when you have checked them, then Save. The stock sizes taken from makers' catalogues are marked unchecked.
Panel sheets and the panel schedule
- Panel sheets. Click Sheets › Sheets (or type
AVSHEETS). Each panel page that holds a panel view gets a sheet, AV-701 and up, at 1:2 with the scale in its viewport title. See Sheets, title blocks and revisions. Empty panel pages get none. - The panel schedule. Click Sheets › Reports (or type
AVREPORT) and choose Panel Schedule for one row for each hole (connector, socket, caption, group, connected-to label, circuit and label colour), or Panel Summary for one row for each panel (make and model, room, form, size, back box and mounting, holes used and spare, connectors and finish). Preview it, save it as CSV or XLSX, or place it on a sheet; see Reports and the Device Listing. - The cover sheet prints a Panel Connectors schedule: each connector the panels use, counted, with its front view.
- Labels. Hole labels and designation strips go to VectorLabel with the Profile B export; see Printing labels with VectorLabel.
Label settings, such as the label format, the prefixes new panels get and which side of the connector a label sits on (above, by default), are in Settings › Panels. A panel's own Label side, and a connector's, win over it.
Good to know
- Check cut-outs before you machine. The generic cut-out sizes, and those of models marked check drawing, are not verified. The RJ45 drawings are RyCAD.AV's own simple drawings, marked generic drawing, with a 14.5 × 19 mm keystone cut-out. Compare them with the manufacturer's drawing first.
- PCB-mount parts are hidden. The store holds Neutrik's PCB-mount models but does not list them or choose them as defaults. A panel that already uses one still draws it.
- The model drawings come from manufacturers' data and are for use on your own computer.
- A panel view has no scale of its own. It is always 1:1; the scale belongs to its panel page.
- Every button of the Panels panel is listed with a one-line description in the command reference.