RyCAD.AV is in beta. These pages describe the current beta builds, which are pre-release software: what they say may change before the first production release, and parts marked Beta are new or still being tested. Downloading the beta needs an account with RyCAD.AV beta access (ask for it here). Tell us if something here is wrong.
A circuit joins one device's socket to another's. You pick the two sockets, and RyCAD.AV draws the route, finds the signal, numbers the circuit and labels its ends.
Circuits are joined to sockets by reference, not by matching names, so renaming a device or moving it never breaks a circuit. Devices come first: see Placing devices. Every button of the Connect panel is listed in the command reference.

To connect two sockets
- Click Connect › Connect (or type
AVCONNECT). The Connect Circuits tab appears on the ribbon and stays until you finish. A socket snap is switched on while the command asks for sockets. - Click the source socket: the socket the signal comes from. Clicking it again only says you already picked it.
- Optionally, click empty points where the route should turn. The route runs horizontally and vertically between them. With grid snap on (F9) the points land on the project grid; with it off they go exactly where you click. You can switch F9 in the middle of the command. To take the last point back, type U; Esc cancels the whole command.
- Click the destination socket. The circuit is drawn.
- Press Enter, or click Connect Circuits › Close Connect, when you are done.
Without turning points, the route is worked out for you, and parallel runs that leave the same device are staggered so they don't lie on top of each other. From a socket on the left or right of a device the route runs horizontally first; from a top or bottom socket it runs vertically first. It turns 3 grid spaces before the destination when it arrives alongside it.
A route through points you clicked is marked as yours: it keeps its shape when later circuits join the same fan-out.
What the preview shows

- Grey is the route through the points so far, following the cursor to where the next click would put its point, with a small square at each point. A label above and to the right of the cursor says SOURCE : SOCKET ->, and adds (U: undo) once there is a point to take back.
- Over a destination socket the label adds the far end, so it reads, for example, STAGE BOX 1 : LINE_OUT 1 -> AMP 1.01 : LINE_IN 1, and the preview is exactly the route the click will draw. It is green when all is well, amber with a warning, and red when the connection would be refused; the reason is in the tooltip. A LAN socket over a DANTE SEC socket, for instance, previews amber: the signals differ. Mismatched types and, with auto-naming on, Cable: C-001 are also shown at the cursor.
- Points that cannot give a clean route also show amber: a stub shorter than one grid space at either socket, or a route that doubles back. If you click anyway, RyCAD.AV draws the automatic route instead and says so on the command line.
A refused connection is reported, and the destination is asked for again with your turning points kept.
The Connect Circuits tab
While AVCONNECT runs, steer it from its tab instead of from the command line. A change shows in the preview as soon as the cursor comes back into the drawing, and your next click connects with the settings as they are then.

AVCONNECT runs. From left to right: the Circuit panel (the signal, From the sockets; the cable type, Signal's default; and Cable Name), Auto Cable Name, Route (Corners: Drawing default (small rounding) and Repeat), Checks (Signal Mismatch and Direction on Warn, Connector Fit and Gender Off), Settings and Close.| Control | What it does |
|---|---|
| Connect Circuits › Signal | The circuit's signal. The button reads From the sockets (the normal case) until you choose one. Click it for a search box: From the sockets first, then this drawing's signals by category. A signal you choose stays for every circuit of the command. |
| Connect Circuits › Cable Type | The cable type. The button reads Signal's default until you choose one. Click it for the drawing's cable types, with those offered for the chosen signal first. It also stays for the whole command. |
| Connect Circuits › Cable Name | The next circuit's cable name only. Empty shows Auto (or the next automatic name, in grey, once auto-naming is on). |
| Connect Circuits › Auto assign cable name | Names every new circuit's cable from a prefix, a number and a suffix. It is described below. |
| Connect Circuits › Prefix, Connect Circuits › Number, Connect Circuits › Suffix, Connect Circuits › Step | The parts of the automatic cable name. Greyed until the tick is on. |
| Connect Circuits › Corners | How new circuits are drawn. The button reads, for example, Corners: Drawing default (small rounding). Each choice shows a small picture of the bend: Drawing default, Square (hard right angles), Small rounding (the house look), Large rounding, Chamfered corners or Off-page arrows. |
| Connect Circuits › Repeat | After each circuit, asks for the next source socket instead of ending. Enter at Next source socket ends. Off by default. |
| Connect Circuits › Signal Mismatch, Connect Circuits › Direction, Connect Circuits › Connector Fit, Connect Circuits › Gender | The four checks, described in the next section. Each shows its current setting: Signal Mismatch and Direction start on Warn, Connector Fit and Gender on Off. |
| Settings… | Opens Settings on its Connect pane while the command keeps running. |
| Connect Circuits › Close Connect | Ends the command. |
Auto assign cable name
Tick Connect Circuits › Auto assign cable name and every circuit the command draws gets a cable name made of the prefix, a padded number and the suffix. The number counts on by the step after each circuit. The digits you type in Connect Circuits › Number set the padding: 001 gives C-001, C-002, and so on. A name another circuit already has is skipped.
- A name typed in Connect Circuits › Cable Name wins for its one circuit, then the automatic name, then the signal's own cable-name template if it has one.
- The drawing keeps the setting and the counter, each project its own, off by default. The number counts in the same change as the circuit, so one undo takes the circuit and its number back, and the number is used again. A refused connection doesn't use a number.
The four checks
Before a circuit is drawn, RyCAD.AV checks it. Each check can be Off, Warn (draw the circuit and show the problem, naming an adapter that would fit where there is one) or Refuse.
| Check | It catches | Choices |
|---|---|---|
| Signal Mismatch | Sockets whose signals neither match nor are compatible. The circuit is always drawn, on the source end's signal, and AVCHECK lists it afterwards. | Warn only on the tab |
| Direction | Input to input, or output to output. | Off, Warn, Refuse |
| Connector Fit | An end's connector that doesn't mate with its socket's. | Off, Warn, Refuse |
| Gender | Two ends of the same gender. | Off, Warn, Refuse |
By default the signal and direction checks warn and the other two are off. The same checks and the corner style are in Settings › Connect, which also has Strict (refuse every problem) and Defaults buttons. Typing AVCONNECTOPTIONS opens that pane. A change there reaches a running AVCONNECT at once, and the checks and corners are remembered for your next session on this computer. For typists, AVCONNECT takes the same settings as keywords at its prompts (Corners, Signal, Type, Name, Auto, Prefix, NUmber, SUffix, STep, Repeat, Mismatch, Direction, Fit and Gender).
What a circuit gets

- A signal, from the sockets. The circuit takes the source socket's signal. If the two sockets carry different signals it is still drawn, and
AVCHECKreports the mismatch. Choose Connect Circuits › Signal to set one yourself. - A layer for that signal. Each circuit sits on
AV-Circuit-Signal-followed by the signal's name, for exampleAV-Circuit-Signal-LINE. The layer is created the first time a signal is used. Change the circuit's signal and it moves layer by itself. Sheets show or hide signals by freezing these layers (see Sheets, title blocks and revisions). - A number from the signal's prefix, such as N001 for a network signal whose prefix is N, while Number circuits as they are drawn is on in Settings › Numbering, which it is by default. If the drawing's signal has no prefix, the circuit is numbered with the fallback prefix X, and the command line says so: The circuit was numbered with the fallback prefix 'X' (a notice, NUM003). In the picture above the four LINE circuits became X001 to X004 because the LINE signal had no prefix, and the LAN circuit became N001. To get L001 instead, give the signal a prefix in Connect › Signals or Settings › Signals; existing numbers are not renumbered. Wire numbers have a layer of their own so they can be hidden on issued sheets. Numbers that are already issued, or locked, never change; Data › Number numbers the rest (see Checking and numbering).
- Connector labels at each end, showing the connector on the cable (XLR3F, TBLK or RJ45, say).
- A cable label, a hexagon with the cable name, once the circuit has a cable name.
- A corner style: the one chosen on the tab, else the drawing's default (small rounding in the house style, set in Settings › Numbering).
A panel connector's centre socket takes a circuit on each side. The circuit uses the side of the centreline your click is on, else the side facing the other end, else the free side. See Panel views and wall plates.
Everything a circuit knows can be edited later in the Inspector: A circuit.
Moving devices
Move a device with AutoCAD's MOVE, the move grip on the selected device, or by dragging it, and its circuits follow when the command ends. They don't rubber-band during the drag. Routes you drew through your own points are re-stubbed at the sockets, and a segment you dragged keeps its place. Whether a single undo takes back both your move and the circuits' follow-up has not been checked in AutoCAD yet.
Grips on circuits
Select a circuit and it shows a grip on each inner segment and one at each socket end.
- Drag a segment grip to move that segment across itself. The route stays square, the stubs at the ends keep their minimum length, and the change survives later device moves. With snap on (F9) the segment lands on the project grid. With snap off, or when you drop it on an object snap or type the point, it stays exactly there.
- Drop an end grip on another socket to move that end there, as Connect › Move End does.
Off-page arrows and Go To
A circuit that leaves a page can be drawn as off-page arrows: one circuit, drawn as two stubs. Before you connect, choose Off-page arrows in Connect Circuits › Corners; or select circuits you have drawn and click Connect › Route Mode (or type AVROUTEMODE). Each stub reads, from the socket outward: the wire number above the line and the connector below it, the hexagon with the cable name, a filled arrowhead, and the far end's device and socket in magenta text. The far-end text follows renames. Selecting one stub shows a faint orange line to the other, on screen only.
Turning arrows back into a line only joins circuits whose ends are on one schematic page. The others stay arrows and are listed.
Connect › Go To (or AVGOTO) jumps to the other end. Pick an off-page arrow, or a route near one end, and it zooms to the far end, selects it and lists every place the circuit is drawn. Pick a device (or select one view first) and it opens a go to window listing every view of the device, the sheets that show it, the devices it connects to circuit by circuit, its equipment item and where it is in the library. Choose a row and click Go: the view is zoomed to and selected, or the sheet's layout is made current.
Connecting many at once
Multi-connect
- Click Connect › Multi-connect (or type
AVCONNECTMULTI). - Click the sending device view, then the receiving one.
- Check the connect sockets window. Its Pair list pairs the sockets By signal, By order or By name, and Facing sides only keeps pairs to the sides of the views that face each other. Every proposed circuit is listed with its signal and any warnings; untick the pairs you don't want. Below, Sockets that get no circuit says why each was left out: occupied, terminated, wrong direction, facing away or no match.
- Click Connect. All the ticked pairs are drawn in one undo step, and each gets an outcome line.
Connect Selected
Select several device views, then click Connect › Connect Selected (or type AVCONNECTSEL). The views are grouped into columns by horizontal overlap, and each column's senders are paired with the next column's receivers, top to bottom. The same pairing window opens. A selection that is a single column says so instead of doing nothing.
Next Free
Click Connect › Next Free (or type AVCONNECTNEXT). Pick the target device, then pick source sockets one after another. Each source goes to the next free socket of the target that can take its signal, with the same four checks. Press Enter to end. The Connect Next Free tab is the Connect Circuits tab without Repeat, and each circuit is one undo step.
Changing circuits you have drawn
| To | Do this |
|---|---|
| Move one end to another socket | Click Connect › Move End (or type AVMOVEEND), pick the circuit near the end to move, then the new socket. The circuit keeps its number, cable and data; its signal follows the new socket unless you set it by hand. |
| Change the corner style | Select the circuits and click Connect › Corners (or type AVCORNERS). Choose square, small rounding, large rounding, chamfer or off-page arrows. With nothing selected it asks for Selected, All, one Signal or Default, the style new circuits take. Only the corners change; jogs, locks and label positions stay. Also in the Inspector's Corners list and on the right-click menu. |
| Switch between lines and arrows | Select the circuits and click Connect › Route Mode (or type AVROUTEMODE) and choose rounded, chamfered, sharp corners or off-page arrows. |
| Swap source and destination | Select the circuits and click Connect › Corners › Flip Circuit (or type AVFLIPCIRCUIT). The drawn routes stay where they are. On a panel connector's centre socket it moves the circuit to the other side instead. |
| Line up cable names | Select circuits, click Connect › Align Names (or type AVALIGNCABLENAMES) and pick a point. Each cable name slides along its own route to where it crosses the vertical line through the point. Only the name moves, not the wire number. |
| Put a moved label back | Right-click the circuit and choose Reset Label Position (or type AVRESETLABEL). Cable names and wire numbers you dragged return to where the style puts them. |
| Bundle circuits along one | Click Connect › ReRoute (or type AVREROUTE), pick the reference circuit, then select the circuits to bundle with it. They run parallel at the stagger pitch and stay bundled when it moves. |
| Hop one circuit over another | Click Connect › Hop Over (or type AVHOPOVER) and pick where two circuits cross. A semicircle is cut into one route. Pick again to remove it. Circuits you selected first stay straight. It is refused while the style's automatic hop-overs are on. |
| Make a multicore | Select the circuits and click Connect › Cable (or type AVCABLE). New makes them the cores of a new multicore, snake, single, tie line, breakout or hybrid cable; Add, Remove and Number change the cores; Editor opens the cable editor. A multicore, snake or tie line gets a callout, an ellipse across the members with the cable name above it. |
Signals and connectors
Every circuit has a signal, and every signal has a prefix, a default connector, a layer and optionally a colour. They live in two editors on the Connect panel.
- Connect › Signals (or
AVSIGNALS) opens Signal Types, with one row per signal: name, family, numbering prefix, default connector, category, description, colour, linetype, lineweight, the layer it gets and how many circuits and sockets use it. Every cell is editable, and each edit is its own undo step. Type a name in Add and it shows the layer it will get. Renaming a signal renames its layer, so its circuits follow. Delete asks which signal the circuits and sockets move to, and Merge into… keeps the old name as an alias. Black and white and Coloured switch the circuits between the house black and one colour per signal. Add from library… brings in signals the library has and the drawing lacks, and Save to library keeps one for every drawing. - Connect › Connectors (or
AVCONNECTORS) opens Connector Types the same way: name, kind (cable, chassis or either), gender, family, description, aliases, which connectors it mates with, and its use. Renaming a connector keeps every socket, device and circuit end on it, and keeps the old name as an alias.
The same lists are panes of the Settings window (Settings › Signals and Settings › Connectors); see Settings and drawing style.
Good to know
- Right-click a circuit for Go to Other End, Move End…, Route Mode, Corners…, Cable, Hop Over…, Reset Label Position, Align Cable Names…, Select Both Devices, Trace…, Renumber Circuits… and Inspector.
- Follow a signal. Data › Trace follows a signal through loop-throughs, panels and multicores; see Checking and numbering.
- Scripts. Under a script or AutoLISP,