RyCAD.AV beta support

Checking and numbering

Find what is wrong in a drawing, trace a signal, search for anything, and number circuits and devices.

Beta documentation

RyCAD.AV is in beta. These pages describe the current beta builds, which are pre-release software: what they say may change before the first production release, and parts marked Beta are new or still being tested. Downloading the beta needs an account with RyCAD.AV beta access (ask for it here). Tell us if something here is wrong.

RyCAD.AV keeps its own record of every device, socket and circuit, so it can check that record for you, follow a signal through it and number things from it. These tools are on the Data panel of the ribbon.

The Data panel opened from the ribbon.
The Data panel of the RyCAD.AV ribbon, opened to show its buttons.

Which tool for what

  • Check gives you a list of what is wrong, once, when you ask.
  • Status is the same kind of list, kept up to date after every command, with the option to ignore items and to fix many at once.
  • Health is the wider list: it also includes what was found when the drawing opened and what was edited without RyCAD.AV, each with a button to fix it.
  • Search, Trace and Grid find things and follow signals.
  • Number, Renumber, Rename Devices and Number Field give circuits and devices their numbers and names.

Check the drawing

  1. To check part of the drawing, select the device views or circuits. To check all of it, select nothing.
  2. Click Data › Check (or type AVCHECK). The RyCAD.AV Check palette opens.
  3. At the top it says what was checked and when (Check of the project at a time), gives the counts (for example 2 error(s) · 1 warning(s) · 14 notice(s) · 2 info) and, when there are errors, Errors need attention before the drawing is issued.
  4. Read the table. Each finding has a Severity, a Code you can quote, what it is About, a Message and a Category. Tick or untick Errors, Warnings, Notices and Info, choose a category (All categories) or type in the search box to narrow it.
  5. Select a finding and click Zoom to go to what it is about (it is selected for you), or Select to select it without moving the view. Fix it, then click Check again.
  6. Copy CSV copies the findings shown, with their codes, to the clipboard. A line of record counts under the table gives the totals for the drawing.
The Check palette listing findings.
The Check palette for a project with 2 errors, 1 warning, 14 notices and 2 info findings: the counts and filters at the top, the table of findings, and the Zoom, Select, Check again and Copy CSV buttons below it.

Examples of what it lists: Circuit with one end detached, Socket signal 'LAN' does not match 'DANTE PRI', Numbering prefix 'U' is shared by 2 signals and Device 'CONSOLE 1' has no room.

Check looks for unknown signals, signals that do not match across a circuit, circuits with only one end connected, references to things that no longer exist, and duplicate device names, socket names, circuit names and circuit numbers. It also lists what was found when the drawing opened: copies and edits made without RyCAD.AV, and records it could not read.

The live Status palette

Click Data › Status (or type AVSTATUS). The Issues tab lists every issue in the project. After each command, undo or reload, it re-checks only the records that changed.

  • Filter by severity, category or text. New only shows just the issues the last change raised.
  • Move through them with ◀ and ▶, Zoom and Select. For an issue about several objects, such as duplicates, Next object steps through them.
  • Fix applies the quick fix to every selected issue that offers one, as one undo step. Quick fixes include naming a device, numbering a circuit and marking a socket spare.
  • Ignore keeps an issue listed but greyed, with who ignored it, when and why. Errors cannot be ignored. Restore brings it back.
  • Check all runs the full check again, and Copy CSV copies what is shown.

The Rules tab lists every rule. Switch a rule on or off, change its severity, or reset it. The rule sets House, Strict (every rule on, for a final issue check) and ConnectCAD-like (the RyCAD.AV-only data and location rules off) set them all at once.

Drawing Health

Drawing Health is the one list of everything wrong with the drawing: the project's checks, what was found when the drawing opened, and anything edited or inserted without RyCAD.AV.

  1. Click Data › Health (or type AVHEALTH). The window RyCAD.AV: Drawing Health opens. It also opens by itself when you open a drawing that has problems, and the command line prints the counts. To turn that off, untick Show Drawing Health when a drawing opens with warnings or errors in Settings › Project.
  2. The top of the window reads Drawing Health: followed by the drawing's file name, with the counts of errors, warnings and notices, and the buttons Fix all safe and Refresh.
  3. Findings are grouped by severity and kind, in groups such as Errors: checks of the project (2). Each finding has Zoom to and Ignore. Select one to see its other buttons: Fix is the default repair (what Reconcile would do), and where there is a choice the alternatives sit beside it, such as reverting an edit instead of adopting it.
  4. Click Zoom to to go to the objects. Ignore hides a finding for this drawing until it changes, for everyone who opens the drawing; List again shows it again.
  5. Fix all safe applies every safe repair in one undo step and leaves anything that needs your choice. Refresh reads the drawing again.
The Drawing Health window.
The Drawing Health window for a drawing with problems: the counts at the top with Fix all safe and Refresh, then the findings in groups such as Errors: checks of the project, each with Zoom to and Ignore.

Every fix is one undo step. If a block from RyCAD.AV is inserted with AutoCAD's own INSERT, the Blocks palette or DesignCenter, Health catches it when the command ends: a device block that a view already draws becomes a new device, and anything else asks what to do with it. Nothing is erased unless you choose it.

Upgrade a drawing from an older release

A drawing remembers which release of RyCAD.AV made it. When you open one from an older release, a window names both releases, lists what the upgrade will change and offers Upgrade…, Use without RyCAD.AV and Close. Until you answer, RyCAD.AV treats the drawing as read-only. To ask again later, click Data › Health › Upgrade (or type AVUPGRADE).

  • Upgrade… renames old layers and text styles to the current names, rewrites the stored data and draws every device and circuit again, in one undo step with a progress bar. It then opens Save As with a suggested name like EXAMPLE THEATRE (RyCAD.AV <version>).dwg in the same folder. Saving over the original is refused, so the older file is never overwritten.
  • Use without RyCAD.AV turns RyCAD.AV off for this drawing until you close it. Nothing is changed.
  • A drawing from a newer release stays read-only. Start the edition that saved it, or update.

Migrate Layers

Click Data › Health › Migrate Layers (or type AVCLASSMIGRATE) to rename old or provisional layers to the current layer names. A report of what would change comes first. Answer Yes and it renames and merges layers, redraws the affected definitions and moves the inserts to the right layers, in one undo step. Layers named by pre-2020 ConnectCAD classes are included. Layer states and layer filters that use the old names are listed for you to review; they are not rewritten.

Edits made without RyCAD.AV

A colleague without RyCAD.AV can move, copy or erase devices and edit text, and the drawing still opens and plots for them (see Sharing drawings with people who don't have RyCAD.AV). When the drawing comes back, Reconcile catches RyCAD.AV up.

  1. Click Data › Reconcile (or type AVRECONCILE). RyCAD.AV also offers it once when it opens a drawing that was edited elsewhere.
  2. At the prompt, press Enter for Apply (take every automatic repair and default), choose Review to be asked about each one, or List to only report.

It re-routes circuits to moved devices, turns a retyped device tag into a rename, puts back derived text that was edited, and lists devices that were erased. It adopts moved or changed racks and equipment, and keeps layer colours, linetypes, lineweights and plot flags changed in the Layer Manager as the project's own where the layer standard allows it, putting them back where it does not. Copies made without RyCAD.AV become Linked by default (another view of the same device), or New devices if you choose; Review shows the dialog where you decide. Closing that dialog means Linked, so a copy is never left unmanaged.

Search, select and trace

  1. Click Data › Search (or type AVSEARCH) and type what to find in Find.
  2. Choose the match mode (contains, whole field, regular expression or is blank), the Field and the Scope: the whole project, the selection, a page or frame, a room, a rack or a signal family. Match case, Related fields and Internal fields widen it.
  3. The hits are listed. Zoom and Select go to one, Select all selects every drawn hit, and Copy CSV copies the list.
  4. To change text in many places, type the new text under Replace and click Preview. Every change is listed with its status (ready, duplicate, collision, blank, locked or read-only). Untick any you do not want, then click Apply, one undo step. Circuit numbers that come from renamed names are kept and locked, unless you tick Regenerate derived circuit numbers.

Select Similar

Select a few device views or circuits, then click Data › Search › Select Similar (or type AVSELECTSIMILAR). At the prompt choose what to select from them: every device of the same definition or the same make and model, their circuits, the devices they connect to, every circuit of the same signal, cable type or cable name, or both ends of the circuits. The result becomes your selection, ready for the Inspector or any AutoCAD command. Right-click on a device view also offers Select Connected Circuits.

The Circuits & Devices grid

Click Data › Grid (or type AVGRID) for a table. Switch between Circuits (number, signal, both ends, cable, sheet and how it is drawn) and Devices (display tag, make, model, category, room, rack, views, sockets used and sheet). Filter by text, sheet, room or signal, or tick Selected only. Rows you pick are selected in the drawing, and what you select in the drawing is highlighted in the grid. Zoom to goes there. The grid is read-only; Inspector opens the selection for editing (see Editing in the Inspector).

Trace a signal

  1. Either select a circuit and click Data › Trace (or type AVTRACE), or click it first and pick a socket.
  2. The Trace palette lists the sources and sinks the signal reaches, then every path with its From, Via and To. Select a path to see its hops below.
  3. Choose the Direction: both ways, downstream or upstream. Click Trace again after you edit, or to change direction.
  4. Zoom and Select go to a hop, a path or the whole trace. Tick Highlight the selected path only to see one path alone, and click Clear highlight to remove the highlight. Copy CSV copies the paths.

The trace follows the signal through loop-throughs and daisy chains, panel connectors, tie lines, jackfield normals (a patch cord interrupts a normal, as standard normalling does), breakouts and multicores, adapters, distribution amplifiers and external references. It notes where a patch cord interrupts a normal, where the signal loops back, where the trace was cut short, where a circuit is connected at only one end and where the path leaves the project. The highlight is temporary: it is never saved or plotted. Esc dismisses it and hides the palette. Trace changes nothing in the drawing.

Numbering circuits and devices

Circuit numbers come from the numbering scheme in Settings › Numbering, which also holds the template new devices are named by. The commands below follow it. A circuit's number can be locked in the Inspector, and a locked number is never changed by any of them. If you have already printed labels, lock the numbers first (see Printing labels with VectorLabel).

Number circuits

  1. Select circuits or device views, or select nothing for the whole project.
  2. Click Data › Number (or type AVNUMBER). The window lists every number before it is issued. Choose what to number (the selection, the project, one signal or one page) and the Order: drawing order, top to bottom, left to right, or by source device.
  3. Click Number. Circuits that already have a number keep it. One undo step.

Clear numbers

Click Data › Clear Numbers (or type AVNUMBERCLEAR) and choose at the prompt what to clear: the selection, the project, a signal or a page. Locked numbers are kept unless you answer Yes to clearing and unlocking them too. Cleared numbers are not handed out again, unless the scheme reuses gaps.

Renumber

  1. Click Data › Renumber (or type AVRENUMBER).
  2. Choose what to renumber (Renumber the circuits of), the Order and what happens to Freed numbers (reused so there are no gaps, or never issued again). Tick Number unnumbered circuits too to include them. Check first runs the numbering pre-check for duplicates, signals without a prefix and rules that match nothing.
  3. The list shows every old and new number with the circuit's ends. Locked numbers are listed and never change. Click Renumber; one undo step puts everything back.

Rename devices from a template

  1. Select the device views to rename, then click Data › Rename Devices (or type AVRENAMEDEVICES).
  2. Type a Template. It can have plain text, one counter and fields: {n}, {n:00}, {A} or {a} for the counter, and {prefix}, {room}, {rack} or another device field. For example, AMP {room}.{n:00}.
  3. Set the start and step, the order (placement, top to bottom, left to right or current name), whether to rename the name or the display tag, and whether Each stem counts on its own.
  4. The list shows every old and new name. Locked names are kept, and names other devices use are stepped over. Click Rename.

If circuit numbers are built from device names, the window asks whether to keep them (and lock them, so printed labels stay right) or regenerate them.

Number a field

Number Field numbers any text field of several objects of one type, the way Vectorworks Spotlight's Number Instruments does.

  1. Select several device views, circuits, racks, rooms, drop points or pages, then click Data › Number Field (or type AVNUMBERFIELD, or right-click and choose Number a Field…). If you selected more than one type, it asks which to number.
  2. Choose the Field: for a device its name, display tag, asset tag, serial number, description, slot or notes; for a circuit its number, cable name, label or notes; and similar fields for the other types.
  3. Set a Prefix, the start (a number that keeps its zero padding, or letters A, B to AA), the step (a minus sign counts down), the padding and a Suffix.
  4. Choose the order: picked one by one (Pick in order…), left to right in rows, top to bottom in columns, or by another field. The list shows each object's value now and after. A locked value is left alone, and a clash with a value another object has is flagged.
  5. Click Number. One undo step.